標準化示范工地驗收內(nèi)容及注意事項.doc
進入下載頁
自從2005年起青島市推廣施工現(xiàn)場標準化管理以來,集團公司先后有5個項目部參加了標準化示范工地的創(chuàng)建工作,并且均順利通過了驗收,標準化驗收內(nèi)容主要分6部分,主要涉及文明施工、安全管理、質(zhì)量管理、隊伍管理、工程監(jiān)理、一票否決等。為以后順利的通過標準化示范工地的驗收,提高公司施工現(xiàn)場標準化管理的水平,現(xiàn)將有關標準化示范工地創(chuàng)建及驗收應注意的問題匯總?cè)缦拢?br />
質(zhì)量管理:
1、門窗洞口用輕體砌塊砌筑,未加混凝土塊或?qū)嵭拇u。導致門窗固定不牢。
2、建材產(chǎn)品進場分類臺帳未注明進場數(shù)量,不同建材產(chǎn)品沒有分類登記。
3、砼試塊試壓強度值離散性大,強度不穩(wěn)定。試塊數(shù)量不足。
4、創(chuàng)標準化示范工地方案缺質(zhì)量方面的控制措施。
5、檢查水泥相關資料、合格證、3天和28天的補強報告。
6、施工組織設計中無質(zhì)量保證體系框架圖。
7、打印的施工日志沒有填寫記錄人
Since 2005, Qingdao City, to promote standardization of management since the construction site, the company has had five projects took part in the creation of standardized work demonstration site, and have passed the inspection, standardization, acceptance mainly in 6 parts, mainly related to civil construction, safety management, quality management, team management, project supervision, one-vote veto, etc.. The adoption of standards for future successful demonstration site inspection, to improve standardization of construction site management company level, now the standard model creation and acceptance of the site should pay attention to the problem are summarized as follows:
Quality Management:
1, window and door openings with a lightweight block masonry, concrete blocks or bricks are not added. Lead to doors and windows fixed is not strong.
2, building materials did not indicate the approach approach ledger classification number, classification of different building materials have not registered.
3, compressive strength of concrete test specimen of the great value of discrete intensity instability. The insufficient number of test blocks.
4, the highest standardized demonstration site programs lack quality control measures.
5, check the cement-related materials, certificate, 3 and 28 days of reinforcing the report.
6, no construction organization design in the framework of quality assurance plan.
7, the printed record of the construction logs were not filled